After-sales Service: | Video Guided Installation, Commissioning, etc. |
---|---|
Warranty: | 1 Year or 1000 Hours, Whatever Occurs First. |
Type: | Self-Starting Diesel Generator |
Installation Method: | Fixed |
Stroke: | Four Stroke |
Cooling Method: | Water Cooling |
Customization: |
---|
Suppliers with verified business licenses
Diesel Generator Set Data | |||
Manufacturer: | Guangxi Dingbo Power Equipment Manufacturing Co.,Ltd | ||
Set Type: | DB-33GF | ||
Prime Power: | 33KW/41.25KVA | ||
Rated Current: | 59.4(A) | ||
Rated Frequency: | 50(Hz) | ||
Start-up time: | 5~6(s) | ||
Power Factor: | 0.8(Lag) | ||
Rated Voltage: | 400/230(V) | ||
Standard Features | |||
|
|
||
Diesel Engine Data | |||
Manufacturer: | WEIFANG HUAFENG Engine | ||
Model: | K4102D-1 | ||
Prime /Standby Power: | 33KW/36.3KW | ||
Rated Speed: | 1500(r/min) | ||
Cycle: | 4 stroke | ||
Cylinder Arrangement: | 4 in line | ||
Displacement: | 3.76L | ||
Bore and Stroke: | 102*115(mm) | ||
Compression Ratio: | 19:1 | ||
Governor Type: | Mechanical | ||
Start battery voltage: | 24V DC | ||
Air Intake System | |||
Air Intake System: | Naturally aspirated | ||
Max Intake Restriction: | 6.1kPa | ||
Burning Capacity: | 6.3m3/min | ||
Air Flow: | 170m3/min | ||
Exhaust System | |||
Exhaust Gas Flow: | 12.6m3/min | ||
Exhaust Temperature: | ≤470ºC | ||
Max Back Pressure: | 3kpa | ||
Fuel System | |||
Fuel System: | Direct Injection | ||
100%( Prime Power) Load: | 266.6g/kwh | ||
Oil System | |||
Total Oil Capacity: | 13L | ||
Oil Consumption: | ≤2.04g/kwh | ||
Oil Pressure at Rated RPM: | 0.30-0.50MPa | ||
Cooling System | ||
Cooling Way: | Water-cooled | |
Total Coolant Capacity: | 28L | |
Max Water Temperature: | 95ºC | |
Alternator Data | ||
Manufacturer: | STAMFORD/ SIEMENS/ MARATHON/ ENGGA / KEPU |
|
Excitation Mode: | Brushless self-excitation | |
Number of phase and Access Act: | 3-phase 4-wire | |
Connecting Type: | "Y" type connecting | |
Alternator Capacity: | 37.5KVA | |
Alternator Efficiencies: | 95% | |
Overload: | (PRP)110% load can run 1h | |
Protection Level: | IP22-IP23 | |
Insulation Class, Temperature Rise: | H/H | |
Telephone Influence Factor (TIF): | <50 | |
THF: | <2% | |
Voltage Regulation, Steady State: | ≤±1% | |
Altitude: | ≤1000m | |
Genset Electrical Performance | |||||||
Voltage Regulation: | ≥±5% | ||||||
Voltage Regulation, Stead State: | ≤±1% | ||||||
Sudden Voltage Warp (100% Sudden Reduce): | ≤+25% | ||||||
Sudden Voltage Warp (Sudden Increase): | ≤-20% | ||||||
Voltage Stable Time (100% Sudden Reduce): | ≤6S | ||||||
Voltage Stable Time (Sudden Increase): | ≤6S | ||||||
Frequency Regulation, Stead State: | ≤5% | ||||||
Frequency Waving: | ≤1.5% | ||||||
Sudden Frequency Warp (100% SuddenReduce): | ≤+12% | ||||||
Sudden Frequency Warp (Sudden Increase): | ≤-10% | ||||||
FrequencyRecoveryTime(100%SuddenReduce): | ≤5S | ||||||
FrequencyRecoveryTime(Sudden Increase): | ≤5S | ||||||
Options | |||||||
Engine | Alternator | ||||||
Heater 2KW & 4KW | Anti Condensation Heater | ||||||
Battery Charger 3.5A & 7A | Permanent Magnet Generator(PMG) | ||||||
Water Separator | Drop CT(For Paralleling) | ||||||
Daily Fuel Tank | |||||||
Fuel Level Sensor | |||||||
Control System | Others | ||||||
Remote Control Panel | Rainproof Type | ||||||
Auto Transfer Switch (ATS) | Soundproof Type | ||||||
Paralleling System | Trailer Type |
Suppliers with verified business licenses